1.7+ billion tons of fly ash are primarily found in landfills or ponded impoundments…and 40 million tons of fly ash continue to be disposed of annually. …interest in recovering this disposed material has increased, partially due to the demand for high-quality fly ash for concrete and cement production during a period of reduced production as coal-fired power generation has decreased in Europe and North America. Concerns about the long-term environmental impact of such landfills are also prompting utilities to find beneficial use applications for this stored ash.
הורדת PDFTriboelectrostatic Beneficiation של הארץ מלא ואפר לטוס קורבן לבריכת
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
Triboelectrostatic Beneficiation of
Land Filled and Ponded Fly Ash
By Lewis Baker, אייל גופטה, סטיבן גייסיקובסקי, and Frank Hrach
האגודה אפר פחם אמריקאי (ACAA) סקר שנתי של ייצור ושימוש של אפר פחם מדווחת כי בין 1966 ו 2011, מעל 2.3 billion short tons of fly ash have been produced by coal-fired utility boilers.1 Of this amount approximately 625 million tons have been beneficially used, mostly for cement and concrete production. עם זאת, the remaining 1.7+ billion tons are primarily found in landfills or filled ponded impoundments. While utilization rates for freshly generated fly ash have increased considerably over recent years, with current rates near 45%, בקירוב 40 million tons of fly ash continue to be disposed of annually. While utilization rates in Europe have been much higher than in the US, considerable volumes of fly ash have also been stored in landfills and impoundments in some European countries.
לאחרונה, interest in recovering this disposed material has increased, partially due to the demand for high-quality fly ash for concrete and cement production during a period of reduced production as coal-fired power generation has decreased in Europe and North America. Concerns about the long-term environmental impact of such landfills are also prompting utilities to find beneficial use applications for this stored ash.
LAND FILLED ASH QUALITY AND REQUIRED BENEFICIATION
While some of this stored fly ash may be suitable for beneficial use as initially excavated, the vast majority will require some processing to meet quality standards for cement or concrete production. Since the material has been typically wetted to enable handling and compaction while avoiding airborne dust generation, drying and deagglomeration is a necessary requirement for use in concrete since concrete producers will want to continue the practice of batching fly ash as a dry, fine powder. עם זאת, assuring the chemical composition of the ash meets specifications, most notably the carbon content measured as loss-on-ignition (לואה), is a greater challenge. As fly ash utilization has increased in the last 20+ שנים, most “in-spec” ash has been beneficially used, and the off-quality ash disposed. Thus, LOI reduction will be a requirement for utilizing the vast majority of fly ash recoverable from utility impoundments.
LOI REDUCTION BY TRIBOELECTRIC SEPARATION
While other researchers have used combustion techniques and flotation processes for LOI reduction of recovered landfilled and ponded fly ash, סט ציוד & Technologies (לתקן) has found that its unique triboelectrostatic belt separation system, long used for beneficiation of freshly generated fly ash, is also effective on recovered ash after suitable drying and deagglomeration.
STET researchers have tested the triboelectrostatic separation behavior of dried landfilled ash from several fly ash landfills in the Americas and Europe. This recovered ash separated very similarly to freshly generated ash with one surprising difference: the particle charging was reversed from that of fresh ash with the carbon charging negative in relation to the mineral.2 Other researchers of electrostatic separation of fly ash carbon have also observed this phenomena.3,4,5 The polarity of the STET triboelectrostatic separator can easily be adjusted to allow rejection of negatively charged carbon from dried landfilled fly ash sources. No special modifications to the separator design or controls are necessary to accommodate this phenomena.
TECHNOLOGY OVERVIEW – FLY ASH CARBON SEPARATION
In the STET carbon separator (איור 1), material is fed into the thin gap between two parallel planar electrodes. החלקיקים טעונים באופן משולש על ידי מגע בין-מפלגתי. The positively charged carbon and the negatively charged mineral (in freshly generated ash that has not been wetted and dried) נמשכים לאלקטרודות הפוכות. The particles are then swept up by a continuous moving belt and conveyed in opposite directions. החגורה מזיזה את החלקיקים הסמוכים לכל אלקטרודה לכיוון קצוות מנוגדים של המפריד. מהירות החגורה הגבוהה מאפשרת גם תפוקות גבוהות מאוד, עד 36 טון לשעה על מפריד יחיד. הפער קטן, high voltage field, זרימת זרם מונה, vigorous particle-particle agitation and self-cleaning action of the belt on the electrodes are the critical features
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
of the STET separator. על-ידי שליטה בפרמטרים שונים של תהליכים, כגון מהירות חגורה, נקודת הזנה, and feed rate, the STET process produces low LOI fly ash at carbon contents of less than 1.5 כדי 4.5% from feed fly ashes ranging in LOI from 4% כדי לעבור 25%.
תאנה. 1 STET Separator processing dried, landfilled fly ash
עיצוב המפריד הוא פשוט וקומפקטי יחסית. מכונה המיועדת לעיבוד 40 טונות לשעה הוא כ 30 טרים. (9 m.) ארוך, 5 טרים. (1.5 m.) רחב, ו 9 רגל., m (2.75 m.) גבוהה. החגורה וההברילים הקשורים הם החלקים הנעים היחידים. האלקטרודות הם נייח, מורכב חומר עמיד כראוי. The belt is made of non-conductive plastic. The separator’s power consumption is about 1 קילוואט-שעה לטון חומר מעובד כאשר רוב הכוח נצרך על ידי שני מנועים המניעים את החגורה.
התהליך יבש לחלוטין., requires no additional materials other than the fly ash and produces no waste water or air emissions. The recovered materials consist of fly ash reduced in carbon content to levels suitable for use as a pozzolanic admixture in concrete, and a high carbon fraction useful as fuel. ניצול של שני זרמי המוצרים מספק 100% פתרון לבעיות סילוק אפר זבובים.
PROASH® RECOVERED FROM LAND FILLS
Four sources of ash were obtained from landfills: sample A from a power plant located in the United Kingdom and samples B, C, and D from the United States. All these samples consisted of ash from the combustion of bituminous coal by large utility boilers. Due to the intermingling of material in the landfills, no further information is available concerning specific coal source or combustion conditions.
The samples as received by STET contained between 15% ו 27% water as is typical for landfilled material. The samples also contained varying amounts of large >1/8 ס מ (~3 mm) material. To prepare the samples for carbon separation, the large debris was removed by screening and the samples then dried and deagglomerated prior to carbon beneficiation. Several methods for drying/deagglomeration have been evaluated at the pilot-scale in order to optimize the overall process. STET has selected an industrially proven, feed processing system that offers simultaneous drying and deagglomeration necessary for effective electrostatic separation. A general process flow sheet is presented in Figure 2.
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
איור 2: Process Flow Diagram
The properties of the prepared samples were well within the range of fly ash obtained directly from normal utility boilers. The most relevant properties for both the separator feeds and products are summarized in Table 2 along with recovered product.
CARBON SEPARATION
Carbon reduction trials using the STET triboelectric belt separator resulted in very good recovery of low LOI products from all four landfill fly ash sources. The reverse charging of the carbon as discussed above did not degrade the separation in any way as compared to processing fresh ash.
The properties of the low LOI fly ash recovered using the STET process for both freshly collected ash from the boiler and ash recovered from the landfill is summarized in Table 1. The results show that the product quality for ProAsh® produced from landfilled material is equivalent to product produced from fresh fly ash sources.
טבלה 1: Properties of feed and recovered ProAsh®.
Feed Sample to Separator |
לואה |
ProAsh LOI® |
ProAsh® Fineness, % +325 רשת |
ProAsh® Mass Yield |
Fresh A |
10.2 % |
3.6 % |
23 % |
84 % |
Landfill A |
11.1 % |
3.6 % |
20 % |
80 % |
Fresh B |
5.3 % |
2.0 % |
13 % |
86 % |
Landfill B |
7.1 % |
2.0 % |
15 % |
65 % |
Fresh C |
4.7% |
2.6% |
16% |
82% |
Landfill C |
5.7% |
2.5% |
23% |
72 % |
Landfill D |
10.8 % |
3.0 % |
25 % |
80 % |
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
PERFORMANCE IN CONCRETE
The properties of the ProAsh® generated from the reclaimed landfill material were compared to that of ProAsh® produced from fresh fly ash generated by the utility boilers from the same location. The processed reclaimed ash meets all the specifications of ASTM C618 and AASHTO M250 standards. The following table summarizes the chemistry for samples from two of the sources showing the insignificant difference between the fresh and reclaimed material.
טבלה 2: Ash Chemistry of low LOI ash.
Material Source |
SiO2 |
Al2O3 |
Fe2O3 |
קאו |
מ.ג.ו |
K2O |
Na2O |
SO3 |
Fresh B |
51.60 |
24.70 |
9.9 |
2.22 |
0.85 |
2.19 |
0.28 |
0.09 |
Landfilled B |
50.40 |
25.00 |
9.3 |
3.04 |
0.85 |
2.41 |
0.21 |
0.11 |
Fresh C |
47.7 |
23.4 |
10.8 |
5.6 |
1.0 |
1.9 |
1.1 |
0.03 |
Landfilled C |
48.5 |
26.5 |
11.5 |
1.8 |
0.86 |
2.39 |
0.18 |
0.02 |
Strength development of a 20% substitution of the low LOI fly ash in a mortar containing 600 lb cementitious/ yd3 (עיין בטבלה 3 להלן) showed the ProAsh® product derived from landfilled ash yielded mortars with strength comparable to mortars produced using ProAsh® from fresh fly ash produced at the same location. The end product of the beneficiated reclaimed ash would support high end uses in the concrete industry consistent with the highly valuable position ProAsh® enjoys in the markets it currently serves.
טבלה 3: Compressive strength of mortar cylinders.
|
7 day Compressive Strength, % of fresh ash control |
28 day Compressive Strength, % of fresh ash control |
Fresh B |
100 |
100 |
Landfilled B |
107 |
113 |
Fresh C |
100 |
100 |
Landfilled C |
97 |
99 |
PROCESS ECONOMICS
The availability of low cost natural gas in the USA greatly enhances the economics of drying processes, including the drying of wetted fly ash from landfills. טבלה 4 summarizes the fuel costs for operations in the USA for 15% ו 20% moisture contents. Typical inefficiencies of drying are included in the calculated values. Costs are based on the mass of material after drying. The incremental costs for drying fly ash for STET triboelectrostatic separation processing are relatively low.
טבלה 4: Drying costs on basis of dried mass.
Moisture content |
Heat Requirement KWhr/T wet basis |
Drying cost / T dry basis (Nat Gas cost $3.45 / mmBtu) |
15 % |
165 |
$ 2.28 |
20 % |
217 |
$ 3.19 |
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
Even with the addition of feed drying costs, the STET separation process offers a low cost, industrially proven, process for LOI reduction of landfilled fly ash. The STET process for reclaimed fly ash is one-third to one-half of the capital cost compared to combustion based systems. The STET process for reclaimed fly ash also has significantly lower emissions to the environment compared to combustion or flotation based systems. Since the only additional air emission source to the standard STET process installation is a natural gas-fired dryer, permitting would be relatively simple.
RECOVERED FUEL VALUE OF HIGH-CARBON FLY ASH
In addition to the low carbon product for use in concrete, brand named ProAsh®, the STET separation process also recovers otherwise wasted unburned carbon in the form of carbon-rich fly ash, branded EcoTherm™. EcoTherm™ has significant fuel value and can easily be returned to the electric power plant using the STET EcoTherm™ Return system to reduce the coal use at the plant. When EcoTherm™ is burned in the utility boiler, the energy from combustion is converted to high pressure / high temperature steam and then to electricity at the same efficiency as coal, typically 35%. The conversion of the recovered thermal energy to electricity in ST Equipment & Technology LLC EcoTherm™ Return system is two to three times higher than that of the competitive technology where the energy is recovered as low-grade heat in the form of hot water which is circulated to the boiler feed water system. EcoTherm™ is also used as a source of alumina in cement kilns, displacing the more expensive bauxite which is usually transported long distances. Utilizing the high carbon EcoTherm™ ash either at a power plant or a cement kiln, maximizes the energy recovery from the delivered coal, reducing the need to mine and transport additional fuel to the facilities.
STET’s Talen Energy Brandon Shores, SMEPA R.D. מורו, NBP Belledune, RWEnpower Didcot, EDF Energy West Burton, RWEnpower Aberthaw, and the Korea South-East Power fly ash plants all include EcoTherm™ Return systems.
STET ASH PROCESSING FACILITIES
STET’s separation process has been used commercial since 1995 for fly ash beneficiation and has generated over 20 million tons of high quality fly ash for concrete production. Controlled low LOI fly ProAsh®, is currently produced with STET’s technology at eleven power stations throughout the U.S., קנדה, the U.K., פולין, and Republic of Korea. ProAsh® fly ash has been approved for use by over twenty state highway authorities, כמו גם סוכנויות מפרט רבות אחרות. ProAsh® has also been certified under Canadian Standards Association and EN 450:2005 תקני איכות באירופה. Ash processing facilities using STET technology are listed in Table 5.
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
טבלה 5. Fly Ash Processing facilities using STET separation technology
השירות / Power Station |
מיקום |
Start of Commercial operations |
Facility Details |
|
דיוק אנרג'י – תחנת רוקסבורו |
צפון קרוליינה ארה"ב |
Sept. 1997 |
2 |
מפרידים |
טאלן אנרגיה – Brandon Shores Station |
מרילנד ארה"ב |
אפריל 1999 |
2 |
מפרידים 35,000 ton storage dome. Ecotherm™ Return 2008 |
ScotAsh (Lafarge / ScottishPower Joint Venture) – תחנת הרכבת לונגאנט |
סקוטלנד ישראל |
Oct. 2002 |
1 |
מפריד |
Jacksonville Electric Authority – St. John’s River Power Park, פל |
פלורידה ארה"ב |
מאי 2003 |
2 |
Separators Coal/Petcoke blends Ammonia Removal |
South Mississippi Electric Power Authority R.D. Morrow Station |
מיסיסיפי ארה"ב |
יאן. 2005 |
1 |
Separator Ecotherm™ Return |
New Brunswick Power Company Belledune Station |
New Brunswick, קנדה |
אפריל 2005 |
1 |
Separator Coal/Petcoke Blends Ecotherm™ Return |
RWE npower Didcot Station |
אנגליה בריטניה |
אוגוסט 2005 |
1 |
Separator Ecotherm™ Return |
Talen Energy Brunner Island Station |
פנסילבניה ארה"ב |
דצמבר 2006 |
2 |
מפרידים 40,000 Ton storage dome |
Tampa Electric Co. Big Bend Station |
פלורידה ארה"ב |
אפריל 2008 |
3 |
מפרידים, מעבר כפול 25,000 Ton storage dome Ammonia Removal |
RWE npower Aberthaw Station (Lafarge Cement UK) |
ויילס ישראל |
בספטמבר 2008 |
1 |
Separator Ammonia Removal Ecotherm™ Return |
EDF Energy West Burton Station (Lafarge Cement UK, Cemex) |
אנגליה בריטניה |
אוקטובר 2008 |
1 |
Separator Ecotherm™ Return |
ZGP (ת"א) (לאפרג' מלט פולין / צ'יץ' יאניקוסודה JV) |
פולין |
מרץ 2010 |
1 |
מפריד |
Korea South-East Power Yeongheung Units 5&6 |
קוריאה הדרומית |
בספטמבר 2014 |
1 |
Separator Ecotherm™ Return |
PGNiG Termika-Siekierki |
פולין |
Scheduled 2016 |
1 |
מפריד |
ZAK -Energo Ash |
פולין |
Scheduled 2016 |
1 |
מפריד |
PREPRINT- המאמר יפורסם ב- Ash ACAA בעבודה, סוגיה 2 2015
CONCLUSIONS
After suitable scalping of large material, drying, and deagglomeration, fly ash recovered from utility plant landfills can be reduced in carbon content using the commercialized STET triboelectric belt separator. The quality of the fly ash product, ProAsh® using the STET system on reclaimed landfill material is equivalent to ProAsh® produced from fresh feed fly ash. The ProAsh® product is very well suited and proven in concrete production. The recovery and beneficiation of landfilled ash will provide a continuing supply of high quality ash for concrete producers in spite of the reduced production of “fresh” ash as coal-fired utilities reduce generation. בנוסף, power plants that need to remove ash from landfills to meet changing environmental regulations will be able to utilize the process to alter a waste product liability into a valuable raw material for concrete producers. The STET separation process with feed pre-processing equipment for drying and deagglomerating landfilled fly ash is an attractive option for ash beneficiation with significantly lower cost and lower emissions compared to other combustion and flotation based systems.
הפניות
[1]American Coal Ash Coal Combustion products and Use Statistics: http://www.acaa- usa.org/Publications/Production-Use-Reports.
[2]ST internal report, אוגוסט 1995.
[3]Li,T.X,. שפר, J.L., באן, H., Neathery, J.K., and Stencel, י.מ.. Dry Beneficiation Processing of Combustion Fly Ash, Proceedings of the DOE Conference on Unburned Carbon on Utility Fly Ash, מאי 19 20, Pittsburgh, PA, 1998.
[4]Baltrus, J.P., Diehl, J.R., Soong, Y., Sands, W. Triboelectrostatic separation of fly ash and charge reversal, Fuel 81, (2002) pp.757-762.
[5]Cangialosi, F., Notarnicola, מ., Liberti, L, Stencel, J. The role of weathering on fly ash charge distribution during triboelectrostatic beneficiation, Journal of Hazardous Materials, 164 (2009) pp.683-688.
AUTHORS
Lewis Baker is the European Technical Support Manager for ST Equipment & טכנולוגיה (לתקן) based in the United Kingdom
Abhishek Gupta is a Process Engineer based at the Separation Technologies pilot plant and lab facility, STET Technical Center, 101 Hampton Ave, נידהם MA 02494 +1-781-972-2300
Dr. סטיבן גייסיקובסקי, Ph.D. is a Senior Research Scientist for ST Equipment & טכנולוגיה (לתקן) based in the New Hampshire.
Frank Hrach is Vice President of Process Engineering based at the Separation Technologies pilot plant and lab facility, STET Technical Center, 101 Hampton Ave, נידהם MA 02494 +1-781-972-2300